C7035A1023 Honeywell Minipeeper UV Sensor - 1" Mounting

Honeywell

No reviews yet Write a Review
SKU:
C7035A1023
$531.84
$505.25
You save $26.59
UPC:
085267039048
Condition:
New
$531.84
$505.25
You save $26.59

Description

Overview:
Compact flame detector for use with flame safeguard controls with ultraviolet amplifiers.

Features:

  • Use with Honeywell Flame Safeguard primary safety controls and burners requiring ultraviolet flame detection.
  • Mounts on a 1 in. sighting pipe by using an integral collar.
  • Protects the sensing tube with a shield.
  • Meets outdoor rain tight requirements of Underwriters Laboratories Inc., NEMA 4 and NEMA 4X.
  • Wires in parallel for difficult sighting applications.
  • Seals against pressures as high as 5 psi (34.5 kPa) when correctly installed.
  • Field-replaceable ultraviolet sensing tube.

    Detects ultraviolet radiation in flames

The Honeywell C7035A1023 is a compact ultraviolet (UV) Minipeeper flame detector designed for use with Honeywell flame safeguard controls on gas, oil, and coal-fired burners. It mounts directly onto a 1-inch sighting pipe using an integral collar and detects UV radiation emitted by combustion flames, providing a reliable flame signal to any compatible 7800 Series or BCS 7700 Series UV amplifier.

This is the standard 0°F to 250°F ambient-rated, 1-inch mount C7035 with 6-foot leadwires. The UV sensing tube is field-replaceable (part no. 129464M), making long-term maintenance straightforward without replacing the entire detector body.

Key Features

  • Ultraviolet (UV) flame detection — detects UV radiation emitted by all flames; end-viewing orientation
  • 1-inch sighting pipe mounting — uses integral collar with 1-inch internal threads; requires a 1-inch sighting pipe at least 2.5 inches long
  • 6-foot (72-inch) leadwires — two leads for connection to compatible UV amplifier
  • Field-replaceable UV sensing tube — replacement tube part no. 129464M; tube can be swapped in the field without replacing the detector body
  • Protective shield — guards the UV sensing tube from physical damage and contaminants
  • Pressure-sealed — seals against pressures up to 5 psi (34.5 kPa) when correctly installed
  • Parallel wiring capable — multiple detectors can be wired in parallel for difficult sighting applications where a single detector cannot achieve adequate flame signal
  • NEMA 3 and NEMA 4/4X rated — meets UL outdoor rain-tight requirements; suitable for outdoor and wet location installations

Specifications

Spec Value
Detection Method Ultraviolet (UV) radiation
Viewing Orientation End viewing
Mounting 1-inch sighting pipe (integral collar)
Minimum Sight Pipe Length 2.5 inches
Lead Length 6 ft (72 in.)
Ambient Temperature Range 0°F to 250°F (-18°C to +121°C)
Maximum Pressure Rating 5 psi (34.5 kPa)
Enclosure Rating NEMA 3, NEMA 4, NEMA 4X
Replacement UV Tube 129464M
Fuel Types Gas, oil, coal, combination
UPC 085267039048
Replaces C7035A1007, C7035A1015

Compatible Amplifiers

The C7035A1023 is designed for use with UV-type flame signal amplifiers in Honeywell 7800 Series and BCS 7700 Series controls:

  • 7800 Series: R7849A, R7849B, R7851B
  • BCS 7700 Series: R7749B, R7249A, R7249B, R7259, R7290

Compatible Primary Controls

Any Honeywell 7800 Series or BCS 7700 Series primary burner control paired with a compatible UV amplifier above, including the RM7890, RM7895, RM7838, RM7823, and related relay modules.

C7035A Model Comparison

The C7035 family all use 1-inch sighting pipe mounting — choose the right model based on temperature rating and lead length:

Model Ambient Temp Range Lead Length Key Difference
C7035A1023 0°F to 250°F 6 ft This unit — standard temp rating
C7035A1031 -40°F to 250°F 6 ft Extended low-temp rating for cold environments
C7035A1080 0°F to 250°F 10 ft Longer lead; 600°F-rated leadwire for high-heat installations

Need ½-inch mounting instead of 1-inch? The C7027A series uses the same UV detection technology but mounts on ½-inch sighting pipe.

Installation Notes

  • Sighting pipe must be threaded to match the detector's 1-inch internal collar threads
  • Sight pipe length and angle must be determined at installation — pipe should tilt slightly downward to prevent soot or dirt accumulation
  • Ordinary glass filters out UV radiation — do not install glass sight ports in the sight pipe
  • If the UV sensing tube continues to glow when no flame is present, replace the tube (part no. 129464M)
  • Not designed for side-viewing applications — end-viewing orientation only

Common Applications

The C7035A1023 is widely used in commercial and industrial boiler flame safeguard systems, process burners, furnaces, and other single-burner combustion equipment where UV flame detection is specified. It is a direct-fit replacement for any existing C7035A1007 or C7035A1015 installation and is commonly paired with RM7890, RM7895, and RM7838 series relay modules equipped with R7849 or R7851 UV amplifiers.