null

MSC-24HAC2 24000 BTU, 18 SEER, 230V/60Hz, R410A, Wifi capable, Heat Pump with 5M copper lineset

(No reviews yet) Write a Review
SKU:
MSC-24HAC2
UPC:
856739008059
MPN:
MSC-24HAC2
Condition:
New
  • MSC-24HAC2 24000 BTU, 18 SEER, 230V/60Hz, R410A, Wifi capable, Heat Pump with 5M copper lineset
  • MSC-24HAC2 24000 BTU, 18 SEER, 230V/60Hz, R410A, Wifi capable, Heat Pump with 5M copper lineset
  • MSC-24HAC2 24000 BTU, 18 SEER, 230V/60Hz, R410A, Wifi capable, Heat Pump with 5M copper lineset
  • MSC-24HAC2 24000 BTU, 18 SEER, 230V/60Hz, R410A, Wifi capable, Heat Pump with 5M copper lineset
  • MSC-24HAC2 24000 BTU, 18 SEER, 230V/60Hz, R410A, Wifi capable, Heat Pump with 5M copper lineset
  • MSC-24HAC2 24000 BTU, 18 SEER, 230V/60Hz, R410A, Wifi capable, Heat Pump with 5M copper lineset
  • MSC-24HAC2 24000 BTU, 18 SEER, 230V/60Hz, R410A, Wifi capable, Heat Pump with 5M copper lineset
  • MSC-24HAC2 24000 BTU, 18 SEER, 230V/60Hz, R410A, Wifi capable, Heat Pump with 5M copper lineset
  • MSC-24HAC2 24000 BTU, 18 SEER, 230V/60Hz, R410A, Wifi capable, Heat Pump with 5M copper lineset
  • MSC-24HAC2 24000 BTU, 18 SEER, 230V/60Hz, R410A, Wifi capable, Heat Pump with 5M copper lineset
  • MSC-24HAC2 24000 BTU, 18 SEER, 230V/60Hz, R410A, Wifi capable, Heat Pump with 5M copper lineset
  • MSC-24HAC2 24000 BTU, 18 SEER, 230V/60Hz, R410A, Wifi capable, Heat Pump with 5M copper lineset
  • MSC-24HAC2 24000 BTU, 18 SEER, 230V/60Hz, R410A, Wifi capable, Heat Pump with 5M copper lineset
Price: $1,290.00

Out of stock

Frequently bought together:

Description

vtronix-classic-america-logo.png

24,000 BTU 18 SEER Wi-Fi Enabled Ductless Mini Split

Model # MSC-24HAC2-I/O

If you are looking to purchase the perfect mini split, look no further. This 24,000 BTU (18 SEER) Mini Split Air Conditioner/Heat Pump that can cool, heat, dry or simply fan your room now has WiFi capabilities. The packaging includes Indoor Unit- Air Handler, Outdoor Unit with a GMCC Compressor, LCD Remote Control plus a FREE installation kit with 16 foot line set, and installation is easy with a licensed and professional contractor. 

Working in 5 modes of standard operation: Auto, Cool, Heat, Fan and Dry. There are also plenty of preset features programmed into it. The Automatic Switch Over mode allows an automated operation. Timer function powers off the mini split after a period of time, saving you money. Sleep mode mirrors the bodies naturally changing temperature levels while we sleep, aiding an uninterrupted night of sleep. In case of a temporary power outage Auto Restart function restarts the system to continue running the same way after power is returned to the unit. Finally, the air louver automatically swings sending airflow, in three speed varieties, throughout a room rather than in a single direction. This unit offers energy savings of up to 30% compared to other conventional mini-splits. Temperature-monitor thermistor protection device comes installed in the evaporator coil, that shuts off compressor if the coil temperature reaches a temperature of 2C, protecting unit from loss of charge, coil freeze up and a dirty-filter operation. Low temperature PTC Strip allows unit to operate in heating down to -13F outdoor temperature.

SYSTEM INCLUDES

  • Indoor Unit- Air Handler.
  • Outdoor Unit- GMCC Compressor, charged with R410A.
  • LCD Remote Control.
  • Free 16 ft (5 m) Lineset.
  • Installation Kit.
  • Instruction Manual + WiFi Manual

FEATURES

  • Elegant, Modern Design.
  • Timer Function.
  • Sleep Function.
  • Automatic Air Swing.
  • Three speed fan & auto-speed blower.
  • Auto-Restart Function
  • Energy savings of up to over 30% compared to conventional mini-splits.
  • Heating operates down to -13F Outdoor Temperature

WARRANTY

Installation of a mini split must be completed by a licensed HVAC company to ensure any issues encountered in the future are not due to improper installation/workmanship. The installation includes electrical, gas and refrigerant connections as regulated by laws, codes and guidelines at the federal, state and local levels. If it is determined that the unit is not functioning due to a manufacturing defect, a replacement part will be sent free of charge up to 1 year from date of shipment of the unit. 

SHIPPING

This item ships on a pallet by Freight. Signature WILL be required for the unit. If you decide to purchase more than 1 unit, it will ship on a pallet via freight. Contact us if you would like to order more than 1 so we can schedule and coordinate the shipment for you.

MANUALS

Download Instruction Manual here

Download Wifi Manual here

Download the Classic America App Here:

Download on the App Store

Download on the Google Play Store

ERROR SIGNALS THAT DISPLAY ON YOUR UNIT

Understanding the error codes that display on the Indoor Unit.

  • E0 - (Common at Start Up) - Lost Communication between Indoor and Outdoor Units (Check Cable #1, Leftmost of 3, may be labelled differently)
  • E1 - Indoor Temperature Sensor Fault
  • E2 - Indoor Pipe Temperature Sensor Fault
  • E3 - Outdoor Pipe Temperature Sensor Fault
  • E4 - Refrigerant System Leakage or Fault
  • E6 - Malfunction of the Indoor Fan Motor
  • E7 - Outdoor Air Temperature Sensor Fault
  • E8 - Outdoor Discharge Temperature Sensor Fault
  • E9 - Outdoor IPM Module Fault
  • EA - Outdoor Current Detect Fault
  • EE - Outdoor PCB EEPROM Fault
  • EF - Outdoor Fan Motor Fault
  • EH - Outdoor Suction Temperature Sensor Fault
  • FX - Advanced Troubleshooting Codes - Contact Tech Support for Assistance

WARNING SIGNALS ON THE DISPLAY

  • CL - Clean Filters

--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Changing the temperature display from Fahrenheit to Celsius degrees or vice versa (F to C)

Step 1. Turn off the unit, by pressing the TEST button on the power plug. Wait for 2 minutes, then press the RESET button on the power plug. Follow with steps 2 and 3 within 3 minutes.

Step 2. Turn on the unit, and set the unit to Cool mode, medium fan speed & 86F (or 30C) temperature.

Step 3. Press the SLEEP button on the remote 8 times within 8 seconds, while pointing the remote towards the unit display.
Wait about 15 seconds and you should hear a beep from the unit, and the displayed temperature should change from Fahrenheit to Celsius degrees or vice versa. Repeat these steps to revert the change.

PLEASE NOTE: AFTER CHANGING UNITS THE AC MAY ENTER ECO (ENERGY SAVINGS) MODE. USE THE MODE BUTTON TO GET IT BACK TO COOL

View AllClose

Warranty Information

1 Year Manufacturer Warranty.

Terms of Warranty
  • Please Register the product within 60 days of receiving your order.
  • 5 Year Warranty on Compressor and 1 Year Warranty on all other parts from date of purchase.
  • We strongly recommend that the unit be installed by a HVAC licensed professional.
  • Although it is rare, we may refuse to honor the warranty if it is not professionally installed by a licensed contractor.

    To register the item for warranty, please complete the form with the requested details to the best of your knowledge.

    Link to Warranty Form

    https://www.acr4sale.com/warranty-form/