Honeywell
S8610U3009 Honeywell Ignition Module
- SKU:
- S8610U3009/U
- UPC:
- 0085267268363
- Condition:
- New
- Availability:
- Ships out the next business day.
Bulk discount rates
Below are the available bulk discount rates for each individual item when you purchase a certain amount
Buy 10 or above | and get 5% off |
Description
Honeywell S8610U3009 Universal Intermittent Pilot Ignition Module replaces multiple field installed intermittent pilot modules supplied by Honeywell, Robertshaw, Johnson Controls and UTEC (HSC). Uses existing intermittent pilot burner. Includes cross reference, instructions and accessories for easy replacement.
FEATURES
- Replaces over 400 White-Rogers, Robertshaw and Honeywell intermittent pilot ignition modules
- Provides ignition sequencing, flame monitoring and safety shutoff for intermittent pilot warm air furnaces and heating appliances
- Provides 100 percent pilot gas shutoff if pilot fails to light; after 5-minute delay, trial for ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed
- For use with Natural or LP gas
- For use in single rod or dual rod / remote sense applications
- Includes spark cable adapters to allow field replacement of both Honeywell and competitive controls without replacing existing spark cable.
IMPORTANT
- TH-W should be connected to 24VAC from the thermostat
- 24V GND should be connected to the un-switched leg of 24VAC transformer
- 24V should NOT be connected if P1 vent damper is not used
INSTALLATION TIPS - LED Error Codes
For quick installation tips Click Here
OFF: No call for heat, TH-W does not have 24VAC present | 4 flashes: Flame sensed out of sequence4 flashes: Flame sensed out of sequence |
Fast Flash: Power up - internal check | 5 flashes: Damper error. Make sure 24V terminal is not connected if P1 plug is not used |
Heart beat (1/2 sec bright, 1/2 dim cycles) Normal start up, ignition sequence started |
6 flashes: Control internal error |
4 secs on then x flashes: Device in run mode. "x" = flame current to the nearest microamp | 7 flashes: Flame rod shorted to ground |
2 flashes: 5 minute retry delay | 8 flashes: Low secondary voltage supply. Check transformer and AC line |
3 flashes: Flame failed during run |
DISCLAIMER
Check the ratings given in the instructions to make sure the S8610U module is suitable for your application. Needs to be installed by experienced licensed professional. Failure to follow instructions carefully can result in injury or cause damage to the product. Explosion hazard with risk of serious injury or death if installed improperly. After installation is complete, check out operation as provided in the instructions. Acr4sale is not responsible for how the product is installed.
DOWNLOAD FILES
Replaces the following Honeywell models
S86A1001
S86A1019
S86A1027
S86A1035
S86B1009
S86B1017
S86B1025
S86C1007
S86C1015
S86C1023
S86C1031
S86C1049
S86C1056
S86D1005
S86D1013
S86D1021
S86E1002
S86E1010
S86E1028
S86E1036
S86E1044
S86E1051
S86E1069
S86E1077
S86E1101
S86E1119
S86E1127
S86F1000
S86F1018
S86F1026
S86F1042
S86F1059
S86F1067
S86F1075
S86F1083
S86F1091
S86G1008
S86G1016
S86G1024
S86G1032
S86G1057
S86G1073
S86H1006
S86H1014
S86H1022
S86H1048
S86H1055
S86H1063
S86H1089
S86H1097
S86H1105
S86H1113
S86H1121
S86H1139
S86H1147
S90A1005
S90B1003
S90B1011
S860C1000
S860D1009
S860D1017
S8600A1001
S8600B1009
S8600B1025
S8600B3005
S8600B3013
S8600C1015
S8600C3003
S8600F1000
S8600F1034
S8600F1042
S8600H1006
S8600H1014
S8600H1022
S8600H1048
S8600H1055
S8600H1063
S8600H1071
S8600H1089
S8600H1097
S8600H1105
S8600H3002
S8600H3010
S8600M1005
S8600M1013
S8600M1021
S8600M2003
S8600M3001
S8600M4009
S8610A1009
S8610B1007
S8610B1015
S8610B1023
S8610B3003
S8610C1005
S8610C1013
S8610C3001
S8610F1008
S8610F1016
S8610F1024
S8610F1032
S8610H1004
S8610H1012
S8610H1020
S8610H1038
S8610H1046
S8610H1053
S8610H1061
S8610H1079
S8610H1095
S8610H3000
S8610H3018
S8610H3026
S8610M1003
S8610M1011
S8610M1029
S8610M3009
S8610M3017
S8610U1003
S8610U1011
S8620C1003
S8620C1011
S8620H1002
S8620H1010
S8620H1028
S8660D1002
S8660D1010
S8660J1008
S8660J1016
S8660J1024
S8660K1006
S8660K1014
S8660K1022
S8670D1000
S8670D1018
S8670D1026
S8670D3006
S8670D3014
S8670E1007
S8670E3003
S8670J3002
S8670J3010
S8670K3000
S8680J1004
14 Reviews
-
Has universal features to replace several older models
This will replace a number of older models via settings. Easy to set and installs as original did. I usually get about 10 years out of Honeywell's modules. I am using on a 2.5M BTU gas burner in a historic hotel and keep a spare on hand just in case. They either work or they don't but are very reliable.
-
Works as advertised
Easy to install. Be careful to follow conversion of connections. One connection location on the old 8600m is slightly different.
-
S8610U3009
I used this to replace a standard pilot light that normally stays on all the time. We have several gas fired kettles for cooking which cycle on and off every hour throughout the day. It is nice to know that when we are not using the cookers there is no flame burning underneath, it only lights up when called for.
-
Honeywell Module
Great price, Fast shipping, No complaints
-
Excelent
Due to the great price I was a little leery butt I received it within a few days and it works perfect.